MICRODUCT CABLE#

OPTIX Cable MICRO Z-VOTKtmd MC302 0.65-1.0kN

9/125 ITU-T G.652D

FEATURES
  • Cable for microduct installation
  • Solid PA-12 jacket
  • Small reduced diameter
  • Designed to cable blowing
  • Water blocking construction
  • Reinforced by FRP central Strengyh member
  • Resistance to high and low temperatures
  • Fully dielectric construction

CABLE CONSTRUCTION#

  1. FRP rod
  2. Optical fibres in 0.25mm coloured coating
  3. Loose tube
  4. Water blocking yarns
  5. Ripcords to tear the outer jacket
  6. Hydrophobic jelly
  7. Filler
  8. PA-12 outer jacket (orange)

OPTIX MICRO Z-VOTKtmd MC302 cables are a family of distributive micro-canalisation cables for micro-tubes that are internally 8mm (for 12 - 92 fibres), 10mm (for 144 fibres) or 12mm (for 102-288 fibres). A light, small in diameter construction, strengthened by a glass yarn rod, PA-12 (0.5mm) orange coat, installation tension strength: 650-1000N, temperature range between -20°C and + 70°C - an equivalent to Micro Z-XOTKtmd.


All cable fibres and tubes are colour coded acording to the "EIA/TIA-598" standard. Each tube is filled with hydrophobic gel to protect the fibres from the effects of moisture and vibration. The cables are meant for installing in primary and secondary tele-technical canalisation by pneumatic (blowing) means.


OPTIX Cable MICRO Z-VOTKtmd MC302 0.65-1.0kN

Product information
Cable
version
The total
amount of
fibres [pcs]
Weight
[kg/km]
(±10%)

Cable
[mm]
(±0.3)

Tube
[mm]
(±0.1)
Supporting
element/
Peripheral
reinforcement
Reinforcing
element
[mm] (±0.1)
Coating
material
& thickness
[mm] (±0.1)
Temp.
range
instalation
Temp.
range
operating
transport
Minimum
bending
radius
temporary
permanent
2T6F 12 26 5.4 1.15/1.45) None FRP 1.60 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
1T12F 12 26 5.4 1.15/1.45) None FRP 1.60 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
2T12F 24 26 5.4 1.15/1.45) None FRP 1.60 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
4T6F 24 26 5.4 1.15/1.45) None FRP 1.60 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
3T12F 36 26 5.4 1.15/1.45) None FRP 1.60 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
4T12F 48 26 5.4 1.15/1.45) None FRP 1.60 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
6T12F 72 26 5.4 1.15/1.45) None FRP 1.60 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
8T12F 96 36 6.1 1.15/1.45) None FRP 2.4 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
12T12F 144 52 7.9 1.15/1.45) None FRP in PE coat (2.4/4.1) PA-12(0.5±0.2) -10° to +50°C -30° to +70°C 20D/10D
24T6F 144 80 9.3 1.15/1.45) None FRP 2.80 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
16T12F 192 52 7.9 1.15/1.45) None FRP 1.60 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
18T12F 216 52 7.9 1.15/1.45) None FRP 1.60 PA-12(0.5) -10° to +50°C -30° to +70°C 20D/10D
24T12F 288 80 9.3 1.15/1.45) None FRP 2.80 PA-12(0.5±0.2) -10° to +50°C -30° to +70°C 20D/10D

Mechanical parameters EN standard IEC standard 12-72F 96-144F 192-216F 288F
Tensile Strength Installation EN 187000 IEC 60794-1-2-E1 650N 800N 650N 1000N
Tensile Strength Operation EN 187000 IEC 60794-1-2-E1 450N 550N 450N 700N
Crushing resistance EN 187000, m.504 IEC 60794-1-2-E3 500N (100x100mm) for 60 sec.
Repeated bending EN 187000, m.507 IEC 60794-1-2-E6 25 cycles(20xD)