FTTX CABLE#

OPTIX Cable MINI LSZH W-NOTKSdD 0.12kN

9/125 ITU-T G.657B3

FEATURES
  • Cable for indoor installation
  • Great flexibility and durability dragging
  • Fully dielectric construction
  • Resistance to high and low temperatures
Enhanced by high quality aramid yarns
  • Solid FR LSZH jacket
  • Small diameter ˜ 3mm

CABLE CONSTRUCTION#

  1. Optical fibres in 0.25mm coating
  2. Coloured buffer 0.9mm (tight buffer or semi-tight buffer)
  3. Aramid yarns
  4. FR LSZH outer jacket (white), UV stabilized


The OPTIX MINI LSZH W-NOTKSdD cables are round indoor cables for use in FTTx systems, strengthened by aramid yarns, a light construction with a small radius, great flexibility against dragging, fully dielectric, dry core, LSZH coat, UV resistant shell, installation tension strength: 120N, temperature range between -20°C and +60°C, an equivalent to W-NOTKSdD.


The construction was designed making sure that the fibres are very well covered, while additionally allowing for easy cable leading and direct wall mount. The G.657A2 and G.657B3 fibres in use feature a small bending radius.

OPTIX Cable MINI LSZH W-NOTKSdD 0.12kN
Product information
Cable
version
The total
amount of
fibres [pcs]
Weight
[kg/km]
(±10%)

Cable
[mm]
(±0.5)

Tube
[mm]
(±0.15)
Supporting
element/
Peripheral
reinforcement
Reinforcing
element
Coating
material
& thickness
[mm] (±5%)
Temp.
range
instalation
Temp.
range
operating
transport
Minimum
bending
radius
temporary
permanent
0T1F 1 7.0 2.8 None Aramid yarns LSZH(0.40) -10° to +50°C -40° to +70°C 20D/15D
0T2F 2 8.5 3.0 None Aramid yarns LSZH(0.40) -10° to +50°C -40° to +70°C 20D/15D

Mechanical parameters EN standard IEC standard 1F 2F
Tensile Strength Installation EN187000 IEC 60794-1-2-E1 120N 120N
Tensile Strength Operation EN187000 IEC 60794-1-2-E1 - -
Crushing resistance EN187000, m.504 IEC 60794-1-2-E3 500N (100x100mm) for 60 sec.
Repeated bending EN187000, m.507 IEC 60794-1-2-E6 30 cycles [(20xD), 1kg]